Error Code C004F

Error Code C004F

Result: 

THE NUMBER OF DISPENSED NOTES DOES NOT MATCH

(Number of requested notes is less than the number of notes dispensed and reported to the Cash Dispenser Unit. The Control Electronics checks after notes are dispensed.)

Solution:

1. Check the number of dispensed notes.

2. Perform a test on the Cash Dispenser Unit.

Error Code C0050

Error Code C0050

Result: The power is cut while notes are being dispensed. The Control Electronics checks.

Solution:

1. Check the number of dispensed notes.

2. Check if there are notes in the return path. If so, remove them.

Error Code C0051

Error Code C0051

Result: CONTROL COMMAND ERROR IN THE CONTROL ELECTRONICS

Solution:

Request to dispense 150 or more notes.

Note: The Control Electronics revises and reissues the command.

Error Code C0052

Error Code C0052

Result: CS1A,1B(NS2) sensor covered. Occurs after notes are dispensed.

Solution:

1. Check if there are notes in the return path. If so, remove them.

2. Check CS1A and 1B(NS2) sensors.

3. Check logic related to CS1A and 1B(NS2) of the Cash Dispenser Unit board.