Error Code C0039

Error Code C0039

Result: GATE OPERATION DETECTION SENSOR (CS3/NS7) ERROR

(Occurs before notes are dispensed during initialization.)

Solution: 

1. Check CS3(NS7) sensor polution.

2. Check the position of the gate solenoid.

3. Check if cable is cut or the connector is wrongly inserted.

4. Check logic related to CS3(NS7) of the Cash Dispenser Unit board.

Need a new dispenser? Check out these ATM dispensers for sale

Error Code C003A

Error Code C003A

Result: Request to display four or more notes.

Solution:

1. Issue the command decrease the number of bills to four or less in the Control Electronics.

Error Code C003B

Error Code C003B

Result: CS15A,15B(NS2) sensor covered. Occurs during initialization

Solution:

1. Check jam and remove jammed notes.

2. Check CS15A and 15B(NS2) sensors for pollution, cable cutting, wrong insertion of connectors, etc.

3. Check logic related to CS15(NS2) of the Cash Dispenser Unit board.

Error Code C0040

Error Code C0040

Result: The cassette was removed while notes were dispensed.

Solution:

1. Check if the cassette has been normally installed.

2. Check if CS7(NS11) can be completely pressed while the cassette is installed.

3. Check if cable is cut or a connector is wrongly installed in CS7(NS11) connector.

4. Check logic related to CS7(NS11) of the Cash Dispenser Unit board.