Error Code C0039
Error Code C0039
Result: GATE OPERATION DETECTION SENSOR (CS3/NS7) ERROR
(Occurs before notes are dispensed during initialization.)
Solution:
1. Check CS3(NS7) sensor polution.
2. Check the position of the gate solenoid.
3. Check if cable is cut or the connector is wrongly inserted.
4. Check logic related to CS3(NS7) of the Cash Dispenser Unit board.
Need a new dispenser? Check out these ATM dispensers for sale
Error Code C003A
Error Code C003A
Result: Request to display four or more notes.
Solution:
1. Issue the command decrease the number of bills to four or less in the Control Electronics.
Error Code C003B
Error Code C003B
Result: CS15A,15B(NS2) sensor covered. Occurs during initialization
Solution:
1. Check jam and remove jammed notes.
2. Check CS15A and 15B(NS2) sensors for pollution, cable cutting, wrong insertion of connectors, etc.
3. Check logic related to CS15(NS2) of the Cash Dispenser Unit board.
Error Code C0040
Error Code C0040
Result: The cassette was removed while notes were dispensed.
Solution:
1. Check if the cassette has been normally installed.
2. Check if CS7(NS11) can be completely pressed while the cassette is installed.
3. Check if cable is cut or a connector is wrongly installed in CS7(NS11) connector.
4. Check logic related to CS7(NS11) of the Cash Dispenser Unit board.